My machine cycles but the forward and reflected powers are the same.
Applies to Solid State systems only


•   The Match Controller and Matching Network are not tuned to the coil. Manually close the press with a part in it and then press and hold the Manual Weld button until the forward power hits the set point and the reflected power is constant. Note the operating values (percentages) of the Tune and Load capacitors. Release the Manual Weld button. Set the Tune preset value to 2% below the operating point and the Load preset value to 1% above operating value. Press Manual Weld again to verify the system reaches full output quickly. If it does not, see question 9.